Health & Medical


Bacterial Viral Filters

Bacterial Viral Filters

67.50

Bacterial Viral Filters

Variants : Adult (Code: 2120) | Paediatric (Code: 2220)

Overview

Electrostatic bacterial and viral filters to protect the patient from airborne microorganisms that may be present in inhaled

air. It also safe-guards the ventilator and its breathing system from patient exhaled airborne microorganisms which helps

reduce the risk of possible cross-infections.

Features

- Individually packed and ready to use

- Designed for breathing circuits and devices

- Lightweight – Low tractive force on connection

- Biocompatible material

- Transparent casing – allows easy inspection of blockages

- Low dead space – minimizes threat of rebreathing

- High quality filtration media with proven efficiency

- Low flow resistance

- ISO connectors

Technical parameters Adult (Code: 2120) Paediatric (Code: 2220)

Filtration efficiency (Bacterial and Viral) >99.999% >99.999%

Mode of filtration electrostatic electrostatic

Tidal volume 250-1000 ml 75-250 ml

Flow resistance <0.3kpa @60 LPM <0.2kpa @20 LPM

Dead space <52 ml <25 ml

Connectors 22M/15F, 15M/22F 15F/22M, 15M

Weight <30g <20g

Luer lock port for CO2 sampling Yes Yes

67.50

Bacterial Viral Filter with Heat and Moisture Exchanger

Bacterial Viral Filter with Heat and Moisture Exchanger

Variants : Adult (Code: 2130) | Paediatric (Code: 2230)

Overview

Electrostatic bacterial and viral filters with heat and moisture element to effectively warm and moisten the air while also

protecting the patient and healthcare workers from airborne microbes.

Features

- Individually packed and ready to use

- Long lasting HME - beyond 24 hours

- Ideal humidification performance - avoids excessive

breathing gas humidification

- Designed for breathing circuits and devices

- Lightweight – Low tractive force on connection

- Biocompatible material

- Transparent casing – allows easy inspection of blockages

- Low dead space – minimizes threat of rebreathing

- High quality filtration media with proven efficiency

- Low flow resistance

- ISO connectors

Technical parameters Adult (Code: 2130) Paediatric (Code: 2230)

Filtration efficiency (Bacterial and Viral) >99.999% >99.999%

Mode of filtration electrostatic electrostatic

Humidity output 34 mg/l @VT-500ml 34 mg/l @VT-250ml

Tidal volume 250-1000 ml 75-250 ml

Flow resistance <0.3kpa @60 LPM <0.2kpa @20 LPM

Dead space <45 ml <20 ml

Connectors 22M/15F, 15M/22F 15F/22M, 15M

Weight <30g <20g

Luer lock port for CO2 sampling Yes Yes

Specifications

-
+

40.00

Heat and Moisture Exchanger

Heat and Moisture Exchanger

70.00

Heat and Moisture Exchanger

Variants : Adult (Code: 2140) | Paediatric (Code: 2240)

Overview

Electrostatic bacterial and viral filters with heat and moisture element to effectively warm and moisten the air while also

protecting the patient and healthcare workers from airborne microbes.

Features

- Individually packed and ready to use

- Long lasting HME - beyond 24 hours

- Ideal humidification performance - avoids excessive

breathing gas humidification

- Designed for breathing circuits and devices

- Lightweight – Low tractive force on connection

- Biocompatible material

- Transparent casing – allows easy inspection of blockages

- Low dead space – minimizes threat of rebreathing

- High quality filtration media with proven efficiency

- Low flow resistance

- ISO connectors

Technical parameters Adult (Code: 2130) Paediatric (Code: 2230)

Filtration efficiency (Bacterial and Viral) >99.999% >99.999%

Mode of filtration electrostatic electrostatic

Humidity output 34 mg/l @VT-500ml 34 mg/l @VT-250ml

Tidal volume 250-1000 ml 75-250 ml

Flow resistance <0.3kpa @60 LPM <0.2kpa @20 LPM

Dead space <45 ml <20 ml

Connectors 22M/15F, 15M/22F 15F/22M, 15M

Weight <30g <20g

Luer lock port for CO2 sampling Yes Yes

Specifications

70.00

Flexible Catheter Mount

Flexible Catheter Mount

55.00

Flexible Catheter Mount

Variants : Without Luer port (Code:4140) | With 4.3 Luer Port (Code:4120) | With 7.6 Luer Port (Code:4130)

Overview

Catheter mounts are available in corrugated tubing, smooth bore tubing and extendible tubing. A variety of patient elbows

are available for gas monitoring, airway suctioning and fibre optic bronchoscopy.

Features

- Low dead space

- Corrugated tubing and smooth bore tubing

- Available in a wide range of configurations and can be

further customised by attaching acssociated products

including filters, face masks etc.

Specifications

- Connectors : 22 M / 15 F patient connection and 22 F ventilator connection

- Luer port : 4.3 mm / 7.6 mm

- Lenght : 15 cm

55.00

Bain Circuit

Bain Circuit

300.00

Bain Circuit

Variants : Standard circuit (Code 1400) | Circuit With Breathing Bag on 1.5m Extended Limb (Code 1401)

Overview

The Bain Circuit uses a high fresh gas flow to deliver anaesthetic gases to the patient and to wash out the exhaled CO2.

The construction of the Bain Circuit uses an inner tube which delivers fresh gases to the patient and an outer corrugated

tube that transports the exhaled gases. This system ensures there is no rebreathing of the exhaled gases when the correct

flow rate is set, this is dependent on the patient’s minute ventilation.

Features

- High sensitive APL valve for uniform pressure response

- High visibility sticker on APL valve with clear position

indications

- Coloured oxygen tubing for better visibility

- 30 M scavenging port for safely handling outlet gas

- 22 F machine port with 22 M adaptor for optional use

- Patient port standard connector 22 M / 15 F

- Patient elbow connector

Specifications

- Peak pressure safely feature ensure < 60 cm H2O under 25 LPM flow

- 30 M scavenging port for safely handling outlet gas

- 22 F machine port with 22 M adaptor for optional use

- Patient port standard connector 22 M / 15 F

300.00

Securinject (Single Use Dental Anesthesia Safety Syringe)

Securinject (Single Use Dental Anesthesia Safety Syringe)

What is Securinject ?

Accidental needle stick injuries and cross infection are serious concerns in modern day dentistry. They pose a significant risk to dental professionals and their patients. Due to their limited awareness and recognition, accidental needle stick injuries and cross infections are known as silent killers.

Securinject is a single use safety syringe for dental anaesthesia. It is an award winning patent protected innovation which prevents accidental needle stick injuries and cross infections in line with OSHA, Health and Safety (Sharp Instruments in Healthcare) Regulations 2013 and European Council Directive 2010/32/EU (the Sharps Directive).

Securinject, on average, provides a 50% cost savings in comparison to a reusable dental syringe per use. This equates to savings of 1200 USD per dentist annually.


Securinject,

Have you experienced an accidental needle stick injury?

Dental professionals are at high risk of accidental needle stick injuries due to recapping, passing of syringes and improper disposal of waste which can transmit blood borne diseases such as Hepatitis B, Hepatitis C, HIV as well as blastomycosis, cryptococcosis, diphtheria, herpes, malaria, mycobacteriosis, syphilis etc. Needle stick injuries may also lead to psychiatric morbidity including post-traumatic stress disorder.

Why is cross infection a problem ?

Cross infection is another challenge for dental offices as reusable dental syringes can be a source of contamination, as they cannot always be safely, consistently and reliably sterilized due to factors such as lack of staff training, co-ordination, equipment and time.


What are the key features of Securinject ?

Securinject syringes are recognized for their easy to use locking mechanism to protect dental professionals from accidental needle stick injuries; ability to safely dismantle used needles for disposal; aesthetically appealing, cost effective and single use design to prevent cross contamination. They are made using the finest materials and most advanced technologies to meet the needs of contemporary dental practice.


35.00

Pressure Line Monitoring (PVC)

Pressure Line Monitoring (PVC)

35.00

Pressure Line Monitoring (PVC)

Variants : 10 cm (Code: 1610B) | 15 cm (Code: 1611B) | 30 cm (Code: 1612B) | 50 cm (Code: 1613B) | 100 cm (Code: 1614B)

150 cm (Code: 1615B) | 200 cm (Code: 1616B)

Overview

Pressure monitoring lines for extending medical tubing and pressure monitoring.

Features

- Individually packed and ready to use

- Disposable, sterile and non-pyrogenic

- Manufacrured from non-toxic medical grade PVC material

- Pressure endurance of > 40 bar

- Suitable for high presssure monitoring and for connection

between syringe infusion pump and patient

- Fitted with luer locks for secure connection

- Various lenghts available according to requirement

- Kink resistant tubing

Connectors Length Prime Volume

M/F 10 cm (Code: 1610B) 0.3 ml

15 cm (Code: 1611B) 0.3 ml

30 cm (Code: 1612B) 0.5 ml

50 cm (Code: 1613B) 0.7 ml

100 cm (Code: 1614B) 1.2 ml

150 cm (Code: 1615B) 1.8 ml

200 cm (Code: 1616B) 2.3 ml

Specifications

35.00

3 way stopcock with extension line

3 way stopcock with extension line

Variants : 7 cm (Code: 1901) | 10 cm (Code: 1902) | 15 cm (Code: 1903) | 25 cm (Code: 1904) | 50 cm (Code: 1905)

100 cm (Code: 1905) | 150 cm (Code: 1906)

Overview

High quality and reliable 3-way stopcock with extension tube for use with any infusion/transfusion devices and blood pressure

monitoring. It also provides an alternative channel for introduction of medicine to the patient with ease of use.

Features

- Individually packed and ready to use

- Disposable, sterile and pyrogenic

- Three arm handle allows for smooth movement to change

fluid direction for facilitating smooth and easy operations

arrow mark indicating direction of flow

- Transparent body - allows easy observation of flow

- Kink-resistant tubing with smooth inner surfaces for laminar,

non-turbulent flow.

- Minimum residual fluid volume

- Pressure endurance of > 40 bar

35.00

Yankauer Suction Set

Yankauer Suction Set

75.00

Yankauer Suction Set

Variants : Standard tip (Code: 1500)

Overview

The suction set can be used for blood and other fluids removal during open surgery while the product is connected to an

external source of suction and its suctioned volume counted as blood loss during surgery.

Features

- Individually packed and ready to use

- Disposable, sterile and non-pyrogenic

- Ergonomictransparent handle offers a firm grip

- Handle with 4 side suction ports smooth atraumatic tip to

withstand negative pressure and ensure continous and

easy suction of fluid

- Kink resistant transparent tubing makes draining visible

- Connection adaptability to vaccum or suction tubes

- Control vent sealed with removable sleeve

- 2 meter tube

75.00

Ventilator Breathing Circuits

Ventilator Breathing Circuits

350.00

Ventilator Breathing Circuits

Overview

State of the art breathing circuits that help deliver oxygen, remove carbon dioxide, and deliver inhalational anaesthetic

agents to patients in an efficient and safe manner. All breathing circuits are available in a wide range of configurations.

Features

- Extremely flexible and crush-proof tube thereby emliminating

any risk of interruption in the ventilation procedure

- Tube diameteris constant whateverthe curvature radius of

the circuit

- Smooth bore prevents condensation build-up which reduces

bacterial growth

- Tube is totally transparent, so the circuit can be constantly

monitored

- Tube features soft flexible connectors that ensure a perfect

seal

Corrugated tube diameter 22 mm 15 mm

Length 150 cm 150 cm

Water trap volume 40 ml 40 ml

Specifications

Technical parameters Adult Paediatric

Connections

22M/15 F patient connection and

22 F ventilator connection

22M/15 F patient connection and

22 F ventilator connection

Luer port 7.6 mm on Y connection and

4.3 mm on elbow connection

7.6 mm on Y connection and

4.3 mm on elbow connection


Corrugated tube diameter 22 mm 15 mm

Length 150 cm 150 cm

Water trap volume 40 ml 40 ml

350.00

Oxygen Mask

Oxygen Mask

60.00

Oxygen Mask

Variants : Oxygen mask (Code 3120)

Features

- Clear face piece allows visual observation of the patient status

- Smooth material used for the cushion allows for a tight seal while providing patient comfort

Specifications

Oxygen Mask

- For adult oxygen therapy

- Adjustable elastic band

- Connector : 6 M

- Star lumen 2 meter flexible PVC oxygen tube

60.00

Venturi Mask

Venturi Mask

150.00

Venturi Mask

Variants : Aerosol mask (Code 3130 | Venturi Mask Kit (Code 3140)

Features

- Clear face piece allows visual observation of the patient status

- Smooth material used for the cushion allows for a tight seal while providing patient comfort

Specifications

Aerosol Mask

- For adult oxygen therapy

- Adjustable elastic band

- Connector : 6 M

- Star lumen 2 meter flexible PVC oxygen tube

Venturi Mask

- For adult oxygen therapy

- Adjustabel elastic band

- Conector : 22 M

- Aluminium nose clip

- 6 colour coded venturi adapters

- Oxygen flow : 2-15 LPM

- Oxygentube : 2 meter flexible PVC star lumen

- Accessories : 22 mm corrugated tube - 15 cm with 22 M / 22 M connector, humidification cup

150.00

Anesthesia Breathing Circuit

Anesthesia Breathing Circuit

258.00

Anesthesia Breathing Circuit

Specifications

- Connections : 22 M / 15 F patient connection and 22 F

ventilator connection

- Luer port : 7.6 mm on Y connector and 4.3 mm on elbow

connector

- Corrugated tube size : 22 mm

- Lenght : 150 cm

- Breahting bag : 2 L

258.00

Pressure Line Monitoring (PE)

Pressure Line Monitoring (PE)

35.00

Pressure Line Monitoring (PE)

Variants : PE tubing with M/F connectors: 10 cm (Code: 1610A) |15 cm (Code: 1611A) |30 cm (Code: 1612A) |50 cm (Code: 1613A)

100 cm (Code: 1614A) |150 cm (Code: 1615A) |200 cm (Code: 1616A)

PE tubing with M/M connectors: 10 cm (Code: 1610C) |15 cm (Code: 1611C) |30 cm (Code: 1612C) |50 cm (Code: 1613C)

100 cm (Code: 1614C) |150 cm (Code: 1615C) |200 cm (Code: 1616C)

Overview

Pressure monitoring lines for extending medical tubing and pressure monitoring.

Features

- Individually packed and ready to use

- Disposable, sterile and non-pyrogenic

- Manufacrured from non-toxic medical grade PVC material

- Pressure endurance of > 40 bar

- Suitable for high presssure monitoring and for connection

between syringe infusion pump and patient

- Fitted with luer locks for secure connection

- Various lenghts available according to requirement

- Kink resistant tubing

Connectors Length Prime Volume

M/F 10 cm (Code: 1610A) 0.2 ml

15 cm (Code: 1611A) 0.3 ml

30 cm (Code: 1612A) 0.4 ml

50 cm (Code: 1613A) 0.6 ml

100 cm (Code: 1614A) 1.0 ml

150 cm (Code: 1615A) 1.5 ml

200 cm (Code: 1616A) 1.9 ml

Connectors Length Prime Volume

M/M 10 cm (Code: 1610C) 0.1 ml

15 cm ( Code: 1611C) 0.2 ml

30 cm (Code: 1612C) 0.3 ml

50 cm (Code: 1613C) 0.5 ml

100 cm (Code: 1614C) 0.9 ml

150 cm (Code: 1615C) 1.4 ml

200 cm (Code: 1616C) 1.8 ml

Specifications

35.00